Redondo Beach whole home iaq system installation: what the audit measures before the quote
LADWP Consumer Rebate and TECH Clean California HEEHRA stack on qualifying Redondo Beach heat pump projects, but the stack only files cleanly when the AHRI Directory match, the Manual J load report, and the HERS verification number all line up on the permit. Permits route through Redondo Beach Building and Safety. Counter permits 1–2 weeks; plan check on coastal zone projects 4–6 weeks. Adding UV-C lamps in the supply plenum and calling the project "whole-home IAQ" without addressing return-side leakage, ventilation rate, or filtration depth. UV-C handles biofilm; it does not handle PM2.5 or VOCs.
ASHRAE 62.2-2022 mechanical ventilation rate formula: Qfan = 0.03 × Afloor + 7.5 × (Nbr + 1) CFM. An 1,800 sq ft, 3-bedroom Los Angeles home calculates to 0.03×1800 + 7.5×4 = 54 + 30 = 84 CFM continuous outdoor air.
Average summer high near 75°F with winter low around 49°F at an elevation of 72 ft and direct ocean exposure. CEC Climate Zone 6. The cooling design temperature for Manual J calculations runs about 84°F, with typical Manual J load landing in the 450-650 sq ft per ton band. Marcus Reyes, P.E. assembles the rebate documentation alongside the engineering report so the filings move on the same timeline as the install. Title 24 §150.0(o).