Pasadena whole home iaq system installation: what the audit measures before the quote
Sits at the base of the San Gabriel Mountains in the Santa Ana wind funnel; one of the hottest summer afternoons in the LA basin with regular 95°F+ stretches and post-2025 chronic ash loading That is the variable that turns a generic whole home iaq system installation into one engineered for the specific block. Average summer high near 89°F with winter low around 45°F at an elevation of 864 ft and roughly 25 miles inland. CEC Climate Zone 9. The cooling design temperature for Manual J calculations runs about 100°F, with typical Manual J load landing in the 350-450 sq ft per ton band. A design temperature of 100°F with the local diurnal swing means the inverter heat pump spends most of its operating hours near 30 percent capacity, and the equipment selected has to modulate down to that band without short-cycling.
ASHRAE 62.2-2022 mechanical ventilation rate formula: Qfan = 0.03 × Afloor + 7.5 × (Nbr + 1) CFM. An 1,800 sq ft, 3-bedroom Los Angeles home calculates to 0.03×1800 + 7.5×4 = 54 + 30 = 84 CFM continuous outdoor air. Total ventilation calc per ASHRAE 62.2 with floor area and bedroom count; HERS verification within ±15% at install.
Marcus Reyes, P.E. specifies based on the lowest bin hour, not the design day, because that is where the homeowner spends the actual operating cost. Electric service in Pasadena is Pasadena Water and Power (municipal); gas is SoCalGas. Equipment selection should match the rebate path that utility offers when the program applies on the day the contract is signed.