Engineering duct redesign and air balancing for Inglewood homes in CEC Climate Zone 8
Duct Redesign and Air Balancing planned by Breathe LA 365 in Inglewood starts with one question: what is the room outcome the homeowner is actually buying? Once that is named, the equipment, the static pressure budget, the AHRI match, and the permit path follow. Airflow that supports a new heat pump, better filtration, and room-by-room comfort is the deliverable, not a brand name.
Engineering anchors for this scope: NEBB / TABB air balance tolerance: ±10% of design CFM at each register, ±5% at supply/return totals; Title 24 Part 6 §150.2(b) leakage targets at 25 Pa: full system replacement ≤15% nominal airflow, duct replacement only ≤10%, existing-duct extension ≤15% AND ≥60% reduction from pre-test; Duct leakage test at 25 Pa via duct blaster (HERS-certified instrument).
Average summer high near 80°F with winter low around 50°F at an elevation of 125 ft and roughly 5 miles inland. CEC Climate Zone 8. The cooling design temperature for Manual J calculations runs about 86°F, with typical Manual J load landing in the 400-600 sq ft per ton band. Every audit produces a written report Marcus signs.