Engineering whole home iaq system installation for Burbank homes in CEC Climate Zone 9
MERV 13 filtration at the air handler is the line item that reshapes the static pressure budget on most Burbank retrofits, and it is the line item that the brochure quote almost always omits. Adding UV-C lamps in the supply plenum and calling the project "whole-home IAQ" without addressing return-side leakage, ventilation rate, or filtration depth. UV-C handles biofilm; it does not handle PM2.5 or VOCs. A 4 inch deep media cabinet at 0.20 in. w.c. clean pressure drop is a different airflow problem than a 1 inch slot filter at 0.08 in. w.c., and the equipment ECM map has to absorb the difference without exceeding total external static.
ASHRAE 62.2-2022 mechanical ventilation rate formula: Qfan = 0.03 × Afloor + 7.5 × (Nbr + 1) CFM. An 1,800 sq ft, 3-bedroom Los Angeles home calculates to 0.03×1800 + 7.5×4 = 54 + 30 = 84 CFM continuous outdoor air.
Average summer high near 89°F with winter low around 45°F at an elevation of 604 ft and roughly 17 miles inland. CEC Climate Zone 9. The cooling design temperature for Manual J calculations runs about 102°F, with typical Manual J load landing in the 350-450 sq ft per ton band. UV-C germicidal lamps at 253.7 nm wavelength; ASHRAE Position Document on Filtration and Air Cleaning lists 1,500–6,000 µW·s/cm² single-pass dose; coil-irradiation reduces biofilm with clear evidence, in-duct upper-air kill rates depend on residence time. The audit measures clean and loaded static separately so the homeowner knows the operating envelope, not just the install-day numbers.